Kiddobloom Children Stainless Steel Cup Safety

Product: Kiddobloom Children Stainless Steel Cup

We, Saku LLC, declare that the above designated product is in conformity with the following product safety regulation, as applicable:

  • US Consumer Product Safety Improvement Act 0f 2008/CPSC-CH-E1002-08.3 total lead in substrate
  • 16 CFR 1500.48 & 49/ 17 CFR 1500.50 accessible sharp points and edges.
  • 16 CFR 1500.50/16 CFR 1501 small parts
  • Labeling requirements: product packaging and labeling, country of origin marking (19 CFR 134.11), verify claims, instructions and tracking label CPSIA.
  • FDA Generally Recognized as Safe (GRAS) evaluation on stainless steel and total chromium (Cr) testing for stainless steel
  • Dishwasher safe test
  • Resistance to corrosion – (for metal components) – 1% salt solution 24 hours ASTM B117 – 2019 (MOD)
  • Model toxics in packaging legislation of the toxics in packaging clearinghouse

The designated product also meets the following European product safety regulation, as applicable:

  • EN 14372:2004 clause 5.4.2.2 migration of certain element
  • BS EN 14350:2020 childcare articles – drinking equipment – safety requirements and test methods, excluding: clause 8 chemical requirements and test methods; clause 9 consumer packaging; clause 10 product information.
  • Council of Europe Resolution CM/RES (2013)9 on metals and alloys used in food contact materials and articles – migration of metal content

Below are some of the results that we would like to share with you. Before reading through the testings, please read the following explanation about detection limit used in testing labs.

Note:

To understand the test result, we need to understand detection limit used in testing labs. There is no zero detection limit, so the labs will set the detection limit to greater than zero on the testing equipment. For example: lead testing with a 10 ppm detection limit and <10 ppm testing result means there possibly is zero to less than 10 ppm of lead in the stainless steel. If the existence of zero lead can not be proven due to the detection limit used in the labs, then no one can claim a product as "lead free" .

 

Total lead in substrate

Test Method: CPSC-CH-E1001-08.3 standard operating procedure for determining total lead (Pb) in children’s metal products (Including children’s metal jewelry), revision 

Lab equipment detection limit 10ppm

Result: <10 ppm

This result means the equipment (with detection limit 10 ppm) can't detect the existence of lead (Pb). We can conclude that there possibly is zero to less than 10 ppm of lead in the product.

The link to CPSC lead requirement is  https://www.cpsc.gov/s3fs-public/pdfs/blk_media_CPSC-CH-E1001-08_3.pdf

 

Kiddobloom baby stainless steel cups passed testing for Lead on substrate

 

Accessible sharp points and edges

The testing lab found that Kiddobloom cups meet the requirement in 16 CFR 1500.48 & 49/ 17 CFR 1500.50 sharp points and edges

Kiddobloom stainless steel baby cups passed testing for sharp edge and point

 

Migration of certain elements based on BS EN 14372:2004

Testing result per protocol in Europe BS EN 14372:2004 standard are:

antimony (Sb) < 5 ppm (first result) and < 5 ppm (second result)

arsenic (As) < 2.5 ppm (first result) and < 2.5 ppm (second result)

barium (Ba) < 5 ppm (first result) and < 5 ppm (second result)

chromium (Cr) < 5 ppm (first result) and < 5 ppm (second result)

lead (Pb) < 5 ppm (first result) and < 5 ppm (second result)

mercury (Hg) < 5 ppm (first result) and < 5 ppm (second result)

selenium (Se) < 5 ppm (first result) and < 5 ppm (second result)

cadmium (Cd) < 5 ppm (first result) and < 5 ppm (second result)

Kiddobloom stainless steel baby or kids cups passed testing for migration of Antimony, Arsenic, Barium, Chromium, Lead, Mercury, Selenium, and Cadmium based on Europe EN 14372 standard

 

Council of Europe Resolution CM/RES (2013)9 on metals and alloys used in food contact materials and articles – migration of metal content

Elements that migrated  from the cups to food in the first, second, and third migration:

aluminum (Al) < 0.1 ppm 

antimony (Sb) < 0.01 ppm

arsenic (As) < 0.001 ppm

barium (Ba) < 0.1 ppm

beryllium (Be) < 0.001 ppm

cadmium (Cd) < 0.001 ppm

chromium (Cr) <0.1 ppm

cobalt (Co) <0.01 ppm

copper (Cu) <0.1 ppm

iron (Fe) < 5 ppm

lead (Pb) < 0.01 ppm

lithium (Li) <0.02 ppm

manganese (Mn) < 0.1 ppm

mercury (Hg) < 0.001 ppm

molybdenum (Mo) < 0.01 ppm

nickel (Ni) < 0.02 ppm

silver (Ag) < 0.02 ppm

thallium (Tl) <0.0001 ppm

tin (Sn) < 5 ppm

vanadium (V) < 0.005 ppm

zinc (Zn) < 1 ppm

 

 

FDA GRAS confirmation that Kiddobloom bowl is made from stainless steel AISI #304

Kiddobloom stainless steel baby cups are confirmed FDA GRAS and made from stainless steel AISI #304

Dishwasher safe

Kiddobloom stainless steel baby cup is dishwasher safe